Range Doubler Multitester  (220-0215)  Specifications  Faxback Doc. # 6537

Ranges

DC Voltage....125 mV/250 mV/1.25V/2.5V/5V/10V/25V/50V/125V/250V/500V/1000V
AC Voltage.............................5V/10V/25V/50V/125V/250V/500V/1000V

DC
Current.25 microA/50 microA/2.5 mA/5 mA/25 mA/50 mA/250 mA/500 mA/5 A/10 A
Resistance............2kOhms/20 kOhms/2 M Ohms/20 M Ohms/(Center Scale 10)
Decibel......................................-20 dB to +62 dB in 8 Ranges.

Accuracy

DC Voltage.....+/-3% of full scale value except: +/-4% of full scale value
                                        for 0.125 - 2.5 V, 500 V and 1000V
AC Voltage......................................+/-4% of Full Scale Value.
DC Current......................................+/-3% of Full Scale Value.
Resistance......................................+/-3% of Full Scale Length

DC
Sensitivity.50,000 Ohms/V when Range Doubler Switch is in V/2.A/2 Position
           25,000 Ohms/V when Range Doubler Switch is in V-Ohms-A Position
AC Sensitivity.....................10,000 Ohms/V when Range Doubler Switch
                                                    is in V/2.A/2 Position
                                     5000 Ohms/V when Range Doubler Switch
                                                   is in V-Ohms-A Position
Meter Movement...4 1/2-Inch, 3-Color, Mirrored Scale, 18 microA Full Scale
Buzzer Continuity..................................<300 Ohms (Approximate)
Batteries...............One 1.5V AA Battery (Cat. No 23-582 or 23-552) and
                                 One 9V Battery (Cat. No. 23-583 or 23-553
Test Leads..............................................Bannana Plug Style
Dimensions.............6 5/8 x 5 3/16 x 1 13/16 Inches (168 x 132 x 46 mm)
Weight...................................................12 Ounces (340 g)

(BR/all-07/11/94)