1200 BPS Internal Modem  (250-1013E)  Specifications   Faxback Doc. # 4759

COMPATIBILITY:                     RECEIVER SENSITIVITY: -41 dBm
        MODEM: Bell 212A-1200/300 bps    TRANSMIT LEVEL: -10.5 dBm
               Bell 103J/113-300 bps    TONE DIAL LEVEL:  0 dBm
       DIALER: "AT" Command Set          LINE IMPEDANCE: 600 ohms
   DATA RATES: 1200 & 300 baud       RINGER EQUIVALENCE: 0.4 B
 SPEED SELECT: Automatic                     MODULATION:
   CMD BUFFER: 40 Characters                   300 BAUD: Frequency Shift
      SPEAKER: On                                        Keyed (FSK)
 DATA FORMATS: 8 bit, no parity; 7 bit        1200 BAUD: Differential Phase
               even, odd, mark or space                  Shift Keyed (DPSK)
               parity.                          DIALING: Pulse (Rotary)
TESTING MODES: Analog (local) loopback                   10 pps
               (initiate & respond).                     Tone (Includes *
               Software command con-                     and #) duration
               trolled.                                  70 ms)


(dkh-07/28/93)